Category: 
Heat and Power
Secondary Category: 
Heaters & Fans

Specs

  • Dimensions (LxWxH): 85x34x49in or 2,159x864x1,245mm
  • Weight without fuel/with fuel: 456/911 lbs or 206.8 / 413.2 kg
  • Fuel capacity: 58.5 gal or 221.4 l
  • Electrical requirement: 120V, 15A, 1ph
  • Stack diameter: sizes 3/2/1 or 12"/16"/20"

Heater

  • Sizing-Air Heat/Drying: 583,528/195,000 cubed feet or 16,524/5,522 metres cubed
  • Fuel input:
    • Stage 1: 272,000 Btu/hr
    • Stage 2: 411,000 Btu/hr
  • Heat output (85% efficiency): 350,117Btu/hr
  • Air output temperature (max.): 250F or 121.1C
  • Fuel consumption: Diesel gph

Blower

  • Type axial (air) / centrifugal (burner): 1/0.25 hp
  • Heat rise
    • Stage 1: 108F or 42.2C
    • Stage 2: 131F or 55C